BFYMP - TURCO 4951X (AMEND.3)
- MSDS: BFYMP
- Manufacturer: TURCO PRODUCTS INC
- Product Name: TURCO 4951X (AMEND.3)
- National Stock Number: 8010-00-943-7127
Product Identification
Product ID:TURCO 4951X (AMEND.3)
MSDS Date:01/01/1985
FSC:8010
NIIN:00-943-7127
MSDS Number: BFYMP
Responsible Party
CARSON, CA 90749
US
Emergency Phone: 614-387-6200
Info Phone: 714-890-3600
Cage: 61102
Contractor
Telephone: 215-419-7890
Cage: 61102
Ingredients
METHYLENE CHLORIDE (SARA III)
CAS: 75-09-2
RTECS: PA8050000
Fraction By Weight: 40.0%
OSHA PEL 500 PPM/C,1000; Z2
ACGIH TLV: 50 PPM, A2; 9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
ISOPROPYL ALCOHOL (SARA III)
CAS: 67-63-0
RTECS: NT8050000
Fraction By Weight: 20.0%
OSHA PEL 400 PPM/500 STEL
ACGIH TLV: 400 PPM/500STEL;9192
TOLUENE (SARA III)
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 15.0%
OSHA PEL 200 PPM/150 STEL
ACGIH TLV: 50 PPM; 9293
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
AMMONIA (SARA III)
CAS: 7664-41-7
RTECS: BO0875000
Fraction By Weight: 3.0%
OSHA PEL 50 PPM
ACGIH TLV: 25 PPM/35 STEL; 9293
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
SODIUM CHROMATE (SARA III)
CAS: 7775-11-3
RTECS: GB2955000
Fraction By Weight: 1.0%
OSHA PEL 0.1 PPM CRO3;CEILING
ACGIH TLV: 0.05 MG CR/M3; 9192
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
Hazards
Effects of Overexposure:INH:DIZZ,HEAD,INTOX,SKIN;IRRIT,DEFAT,MAY ABSORB
TOXIC AMT;EYES:MAY CAUSE PERMANENT DAMAGE/SEV IRRIT.
First Aid
First Aid:SEV CHEST PAIN MAY INDICATE DANGER LEV OF CARBOXY
HEMOGLOGIN.GET MED ATTN;SKIN:WASH W/SOAP & WATER;EYES:FLUSH W/LG
AMT OF WATER;INH:REMOVE TO FRESH AIR.GIVE OXY/CPR IF
NEEDED;INGEST:DO NOT INDUCE VOMI T,DILUTE W/H*WO OR MILK.GET MED
HELP FOR ANY PROBL
Fire Fighting
Flash Point:NONE TO BOIL
Lower Limits:UNK
Upper Limits:UNK
Extinguishing Media:CO2,FOAM
Fire Fighting Procedures:USE SELF CONTAINED BREATHING APPARATUS
Unusual Fire/Explosion Hazard:THERMAL DECOMP MAY EMIT OXIDES OF C &
CL.MOD HEAT MAY CAUSE DRUMS TO BUILD INT PRESSURE & RUPTURE.
Accidental Release
Spill Release Procedures:VENTILATE AREA.WEAR PROTECTVE EQUIP.ELEMINATE
IGN SOURCE.STOP LEAK W/O RISK.DIKE/CONTN SPILLAGE.WIPE UP OR ABSORB
SPILLAGE ONTO ABSORBENT MATL.RECOVER IN DRUMS/CONTNRS WHICH ARE
SUITABLE FOR SHIPMENT TO DISPOSAL LOCATION.
Handling
Handling and Storage Precautions:STORE AWAY FROM HEAT/IGN SOURCES.USE
CARE IN OPENING DRUMS TO AVOID SPURTING OF CONTENTS.PROTECT CONTNRS
AGAINST PHYSICAL DAMAGE.
Other Precautions:VAP HEAVR THAN AIR WILL TRAVL ALONG GRD COLLECTING IN
LOW AREAS SUCH AS SUMPS.PERSONS ENTERING THIS AREA SHOULD USE
PROTEC EQUIP & BE OBSERVD WHILE IN THE AREA;AVOID REPEATD CONT W
SKIN/EYES.
Exposure Controls
Respiratory Protection:SELF-CNTND BRTHG APP,POS PRESSURE HOSE
MAS/AIR-LINE MASK W/FACEPIEC
Ventilation:LOCAL EXHAUST TO MINIMIZE VAPOR CONCENTRATION
Protective Gloves:NEOPRENE
Eye Protection:CUP TYPE/RUBBR FRAMD GOGG
Other Protective Equipment:SOLVENT RESISTANT BOOTS & APRON(NEOPRENE)
Supplemental Safety and Health
Chemical Properties
HCC:T4
Boiling Pt:B.P. Text:105F=40.6C
Vapor Pres:380
Vapor Density:>1
Spec Gravity:1.0100
Evaporation Rate & Reference:FASTER THAN BUAC
Solubility in Water:APPRECIABLE
Appearance and Odor:YELLOW VISOUS LIQUID,AMMONICAL ODOR
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS,CORROSIVE MATL
Stability Condition to Avoid:SOURCE OF HEAT/IGNITION
Hazardous Decomposition Products:TOXIC OXIDES OF CARBON &
CL*2(PHOSGENE,CARBON MONOXIDE)
Disposal
Waste Disposal Methods:MFGR RECOMMENDS ONE OR ALL OF THE FOLLOWING
METHODS:(1) INCINERATE IN APPROVED INCINERATOR W/APPROP FUME
SCRUBBER;(2) LANDFILL IAW LOCAL,STAE,FED REGS;(3) TRANSFER/SHIP TO
RECLAIMING FACILITY FOR SOLV ENT RECOVERY.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.